5) Secure cooktop from underneath with the supplied clips and screws (see Figure 12).
Installing the Pressure Regulator
WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause
gas leakage and personal injury. Always use new flexible connectors when installing a gas appliance.
To reduce the possibility of gas leakage, apply Teflon tape or a thread compound approved for use
with LP or Natural gases to all threaded connections.
• This cooktop is set for natural gas and is designed to operate at 5” water column pressure. The
gas supply is required to provide a minimum of 6” to a maximum of 14” water column pressure to the
cooktop regulator.