Napoleon WSC43BA-KT Wi-Fi Thermostat

User Manual - Page 44

For WSC43BA-KT.

PDF File Manual, 54 pages, Download pdf file

Loading ...
Loading ...
Loading ...
W415-4094 / 06.10.22
44
meet your thermostat
EN
on according to the ‘Compressor Stage2 Temp Delta’
(non adjustable) and ‘Compressor Stage1 Max Runtime’
(adjustable) and second stage furnace heating will be turned
on according to ‘Aux Heat Stage 1 Max Runtime’ in Menu
> Settings > Installation > Advanced setting.
Green: The values in your green switching table are
formulated to help in prioritizing GHG savings and reducing
your carbon footprint when satisfying your heating demand.
In this mode, the second stage HP heating is will be turned
on according to the ‘Compressor Stage2 Temp Delta’
(non adjustable) and ‘Compressor Stage1 Max Runtime’
(adjustable) and second stage furnace heating will be
turned on according to ‘Aux Heat Stage 1 Max Runtime’
(adjustable) and ‘AUX Heat Stage 2 Temp Delta’ (non
adjustable) in Menu > Settings > Installation > Advanced
setting.
Nighttime: Run quiet operation of your unit at night,
limiting fan speed and utilizing low stage heating for as
long as possible. In this mode, second stage HP heating
is controlled by values in ‘Compressor Stage2 Temp Delta’
and ‘Hybrid Max Heat Pump Runtime’ and second stage
furnace heating will be turned on according to the ‘Aux Heat
Stage 1 Max Runtime’ and ‘AUX Heat Stage 2 Temp Delta’
in Menu > Settings > Installation > Advanced setting.