Frigidaire FCGD3000ES1 Coin Operated Clothes Dryer - Gas Powered

Installation Instructions - Page 3

For FCGD3000ES1.

PDF File Manual, 15 pages, Read Online | Download pdf file

FCGD3000ES1 photo
Loading ...
Loading ...
Number
of
90°
Turns
0
I
2
3
4
MAXIMUM LENGTH
of 4" (10.2 cm) Dia. Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
(10.2 cm)
60ft,
52ft.
44 ft.
32ft.
28ft.
Louvered
(18.28 rn)
(15.84 m)
(13.41 m)
(9.75 m)
(8.53 m)
(6.35 cm_
48 ft.(14.63 m)
40 ft.(12.19 m)
32 ft. (9.75 m)
24ft. (7.31 m)
16ft. (4.87 m)
Number
of
90°
Turns
0
1
2
3
MAXIMUM LENGTH
of 4" (10.2 cm) Dia. Flexible Metal Duct
VENT HOOD TYPE
(Preferred)
(10.2 cm)
30ft.
22ft.
14ft.
Louvered
(9.14
(6.71
(4.27
16.35cm)
m) 18 ft. (5.49 m)
m) 14ft. (4.27 m)
m) 10ft. (3.05 m)
NOT RECOMMENDED
INSTALL MALE FITTINGS IN CORRECT DIRECTION
Ininstallations where the exhaust system isnot described in the
charts, the following method must be used to determine if the
exhaust system is acceptable:
1. Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.
3. Readthe measurement on the manometer.
4. The system back pressure MUST NOT be higher than
0.75 inches of water column. If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable. If the manometer reading is
higher than 0.75 inches of water column, the system is
too restrictive and the installation is unacceptable.
Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could affect the
performance of the dryer:
Only the rigid metal duct work should be used.
Venting vertical through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.
Running the exhaust system through an uninsulated area
may cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause
an increase in vent restriction.
The exhaust system should be inspected and cleaned a
minimum of every 6 months with normal usage. The more
the dryer is used, the more often you should check the
exhaust system and vent hood for proper operation.
EXHAUSTDIRECTION
All dryers shipped from the factory are set up for rearexhausting.
However, on electric dryers, exhausting can be to the right or
left side of the cabinet or the bottom of the dryer.On gasdryers,
exhausting can be to the right side of the cabinet or the bottom
of the dryer. Directional exhausting can be accomplished by
installing Exhaust Kit, P/N 131456800, available through your
parts distributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
3
(9.5 cm)
GAS SUPPLY REQUIREMENTS
Replace copper connecting pipe that is not
plastic-coated. Stainless steel or plastic-coated brass MUST
be used.
I. Installation MUSTconform with localcodes,or in the absence
of local codes,with the National FuelGasCode, ANSIZ223. I
(latest edition).
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
4. The gas supply line MUST have an individual shutoff valve.
5. A 1/8 inch (0.32 cm) N.RT.plugged tapping, accessible for
test gauge connection, MUST be installed immediately
upstream of the gas supply connection to the dryer.
6. The dryerMUSTbe disconnected from the gassupply piping
system during any pressure testing of the gassupply piping
system at test pressures in excess of 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the gas supply piping
system during any pressure testing of the gassupply piping
system at test pressures equal to or lessthan 1/2 psig (3.45
kPa).