Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure)
and the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated on
the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should
be given to the relevant requirements regarding
ventilation.
Category II2H3+ (GB)
GAS SAFETY (INSTALLATION & USE)
REGULATIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the
law. In the UK,gas safe registered installers work to
safe standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to install
the cooker correctly could invalidate the warranty
liability claims and could lead to prosecution.
LOCATION
The cooker may be located in a kitchen, kitchen/diner
or a bed-sitting room, but not in a room containing a
bath or shower. The cooker must not be installed in a
bed-sitting room of less than 20m
3
.
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a basement.
Installation
This operation must be perfomed
by a qualified technician
MODEL NUMBERS:
ID60G2
ID60G2/UK
ID60G2
ID60G2/UK
ID60G2
ID60G2/UK
ID60G2
ID60G2/UK
These Models are set to burn Natural Gas(G20).
Appliances that can be converted to other gases,
such as Butane (G30) or Propane (G31), are listed
on the data badge. Always check the data badge.
4
EN
PROVISION FOR VENTILATION
This unit may be installed and used only in
permanently ventilated rooms according to the British
Standards Codes Of Practice: B.S. 6172/B.S. 5440,
Par. 2 and B.S. 6891 Current Editions. The following
requirements must be observed:
contain an openable window
a. The room containing the appliance must
or an acceptable alternative
such as an adjustable lovre or hinged panel opening
direct to outside air.
The cooker should not be installed in a bed sitting
in a room of volume less than 5m3
an air vent of effective area of 100cm2 is required,
if it is installed in a room of volume between 5m3
and 10m3 a supplementary air vent area of 50cm2 is
required, if the volume exceeds 10m3
no air vent is
room with a volume of less than 20m3. If it is installed
required.
However, if the room has a door or a window which
opens directly to the outside no air vent is required
even when the volume is between 5m3 and 10m3b.
During prolonged use of the appliance you may
consider it necessary to open a window to the
outside to improve ventilation.
If there are other fuel burning appliances in the
same room, B.S.5440 Part 2 Current Edition, should,
be consulted to determine the requisite air vent.
TECHNICAL DATA
Gas connection Rp ½ (½” BSP female)
Pressure test point Front left hotplate
injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a
3 pin 13 amp plug
230/240V a.c. 50
Hz.
13A fuse.