TROUBLESHOOTING (cont’)
Trouble
Probable Cause
Remedy
Odor Bacteria may be present.
Clean and disinfect cabinet following Care
and Maintenance instructions.
Add EPA registered Bacteria Treatment
according to instructions on the bottle.
It may be necessary to replace the wick if
odor persists.
“CF” message does not
appear even when wick is
dirty or humidifier
performance is clearly
reduced.
Loss of power or a
power failure has caused
the CF message to
prematurely reset.
Replace wick.
Display blinks or fan moves
slightly when humidifier is
plugged in.
Normal
No action required.
Alternating “F” and room
humidity displayed.
Reservoir is empty.
Float is not activating
switch on chassis
Fill humidifier with water.
Reposition chassis so that float
and switch are aligned.
Alternating “CF” and room
humidity displayed.
Wick may be dirty.
Replace wick, if needed
Unplug unit for 30 seconds and plug back in
to clear display.
Display flashes “20”
ROOM Humidity is lower
than 20%.
Unit cannot read below 20%.
Set humidistat to 25-35% and increase
fan speed for several hours to
raise humidity. When Room reaches
25% the display will return to normal.
Display flashes ”—“
Unit initiating.
• Room humidity is over 95%.
Room humidity will display after
initiation is complete.
Will remain until humidity drops
below 95%.