Westinghouse WFE946SA Freestanding Electric Oven/Stove

User Manual - Page 44

For WFE946SA. Also, The document are for others Westinghouse models: WFE912SA, WFE914SA, WFE916SA, WVE916SA

PDF File Manual, 48 pages, Read Online | Download pdf file

WFE946SA photo
Loading ...
Loading ...
Loading ...
44
ELECTRICAL & GAS CONNECTION LOCATIONS
INSTALLING THE GAS COOKER
GAS TYPE NATURAL GAS UNIVERSAL LPG
Supplypressureatinletto
applianceregulator(iffitted)
1.13(kPa)
Minimum
2.75*
(kPa)
Operatingpressureat
appliancetestpoint
1.00(kPa)2.75(kPa)
*Iftheregulatorisplacedupstreamofthecookerinlet,as
isnormalforcookersoperatingonLPG,thenthesupply
pressureandoperatingpressurearethesame.
Thefollowingtableshowstheinjectorsizesforeach
burner.
INJECTOR ORIFICE NATURAL GAS UNIVERSAL LPG
Lowheatburner1.00mm0.55mm
Mediumheatburner1.35mm0.70mm
Highheatburner1.60mm0.90mm
Intenseheatwokburner1.75mm1.00mm
GAS CONNECTION
Readthesepointsbeforeconnectingtothegassupply:
•Theapplianceispresetfornaturalgasuse,ifLPGis
tobeusedseeConversiontoLPGsection.
•Gasinstallationmustbemadeinaccordancewith
AS5601,thelocalgasfittingregulations,municipal
codesandotherstatutoryregulations.
•Thegasconnectionpointisa½”BSPexternalthread
locatedattherearoftheapplianceasshown.
•Aregulatorissuppliedwhichmustbefittedtothe
appliance.Ensurethatwhenfittedthepressuretest
pointofregulatorisaccessible.
•Theregulatoristobefittedtotheappliance
connectionpoint,thenfithardpipingfromthe
regulatortotheconsumerhardpiping.Ensurethe
installationallowsthewithdrawaloftheappliance.
Donotuseaflexiblehosetoconnecttheapplianceto
thegassupply.
CHECKING PIPING SIZE
Toworkoutasuitablepipesizeforconnectionuse:
Theinformationinthistable
GAS TYPE NATURAL GAS UNIVERSAL LPG
WFE912&WFE91449.6MJ/h40.9MJ/h
WFE91658.6MJ/h47.4MJ/h
Informationaboutthelengthofrun,numberofelbows,
teesandbends,theavailableservicepressureandthe
supplyrequirements.
NOTE: AS/NZS5601.1 will help you with this matter.
INSTALLATION
MODELS WFE912, WFE914, WFE916 AND WFE946
GAS PRESSURES
Thefollowingtableshowsthesupplyandoperating
pressuresforvariousgases.
168
95
Electricalconnectioncable
806
411
Gasconnectionpointtoregulator
Models:WFE912,WFE914,WFE916
Electricalcable
entrypoint
Models:
WFE912,WFE914,
WFE916,WFE946
Loading ...
Loading ...
Loading ...