Bosch 0603663E03 cross line laser UniversalLevel 360 with premium tripod (vertical + horizontal laser lines incl. 360° for alignment throughout the entire room)

User Manual - Page 21

For 0603663E03.

PDF File Manual, 192 pages, Read Online | Download pdf file

0603663E03 photo
Loading ...
Loading ...
Loading ...
English | 21
u Hold the measuring tool by the intended gripping surface (1) only, so
as not to influence the measurement.
u Do not attach any stickers or labels to the sensor area(6) on the rear
of the measuring tool. Metal labels in particular will affect measuring
results.
Do not wear gloves when taking measurements and
make sure that you are properly earthed. If you are not
properly earthed, the identification of live wires may be im-
paired.
When taking measurements, avoid devices that emit
strong electric, magnetic or electromagnetic fields. If
possible, deactivate all tools whose radiation could interfere
with the measurement and switch off the corresponding
functions or tools.
Starting Operation
Switching on/off
u Before switching on the measuring tool, ensure that the sensor
area(6) is dry. If necessary, use a cloth to dry the measuring tool.
u If the measuring tool has been exposed to a significant change in
temperature, leave it to adjust to the ambient temperature before
switching it on.
To switch on the measuring tool, push the on/off switch(2) down.
The measuring tool carries out a short self-check and calibrates itself auto-
matically. Once the indicator light(3) turns green, the measuring tool is
ready to use.
To switch off the measuring tool, push the on/off switch(2) up.
If no measurement takes place for approx.10minutes, the measuring tool
automatically switches off to save the batteries.
Note: When the measuring tool has switched off automatically, the on/off
switch(2) will still be in the "on" position. To switch the measuring tool on
again, first switch it off and then switch it on again.
Bosch Power Tools 1 609 92A 7L4 | (26.04.2022)