78
FlexFit Pro
DC bus over/under voltage protection
Bus voltage>overvoltage shutdown value: the compressor stops, then switches into the bus overvoltage protection.
Bus voltage<overvoltage recovery value, cancel the bus overvoltage protection.
Bus voltage<under voltage shutdown value: the compressor stops, then switches into the bus under voltage
protection.
Bus voltage<voltage recovery value, cancel the bus under voltage protection.
AC input over/under voltage protection
Drive comes with AC voltage detection, when input voltage is too low, the input current will be too high, damage can
occur
Input voltage<under voltage shutdown value, the compressor stops, then switches into the input under voltage
protection.
Input voltage>voltage recovery value, cancel the under voltage protection.
Drive comes with AC voltage detection, if the input voltage is too high, damage can occur.
Input voltage>over-voltage shutdown value, the compressor stops, then switches into the input overvoltage
protection.
Input voltage<over-voltage recovery value, cancel input over-voltage protection.
Communication error:
Drive priority detects the model code after power is on for 30 seconds .
Compressor type Model Code
TNB220FFEMC 0x02DC
TNB306FFEMC 0x02DD
If the model code is not within the model range or or the correct data is not received within the 30 seconds, the unit
will go into a communications failure mode and will shut down.
When the correct data is within the model code range the error will be canceled.
Note: For debug mode, when the model code is not within the range of models, sentenced to communication
failure; when the model code within the model range, then cancel the error
PFC switch value:
When PFC sampling current>PFC open switch current and the DC bus average voltage<PFC open switch voltage,
then opening PFC;
When PFC sampling current<PFC off switch current, off PFC.
Protection value
Compressor type TNB220FFEMC:
No. Error Description
Device
Protection
Value
1Compressor phase current Limit frequency protection shutdown current value (RMS) 18A
2Compressor phase current Limit frequency protection decrease frequency current value (RMS) 13A
3Compressor phase current Limit frequency protection recovery current value (RMS) 10A
4PIMTemperature shutdown protection 105°C
5Drive input current limit frequency protection shutdown current value (RMS) 23A
6Drive input current limit frequency protection decrease frequency current value (RMS) 18A
7Drive input current limit frequency protection recovery current value (RMS) 13A
8AC input overvoltage shutdown value 280V
9AC input overvoltage recovery value 265V
10 AC input under voltage shutdown value 155V
11 AC input under voltage recovery value 185V
12 DC bus overvoltage shutdown value 390V
13 DC bus overvoltage recovery value 380V