Performance Data Sheet
SmartWater FiltrationSystem
GSWFCartridge
This system has been testedaccordingto NSF/ANS142/53for reductionof the substances listed below.
The concentrationof the indicated substances in water enteringthe system was reducedto a concentration
less than or equal to the permissiblelimit for water leaving the system, asspecified in NSF/ANS/42/53.*
(100%safety factors built in for unmetered usage)
Parameter
Chl(wine
T&,O
Particulate""
USEPA
MCL
J[lz[]uent
Average
1.845 mg/L
, ,2o,
143,.,a3 #/mL
Standard No. 42: Aesthetic Effects
Influent Challenge Effluent
Concentration Average Maximum
2.0 mg/L+lO% < 0.05 mg/L 0.05 mg/L
at least ]0,000 particles!mE 29.83 #/mL 140 #/mL
% Reduction
Average Minimum
> 97.29% 96A3%
99.98% 99.91%
Min. Required
Reduction
>_5O%
>_85%
Standard No. 53: Health Effects
Parameter Effluent
Tulbidit}
()_ts
[_ead at pH 65
[_ead at pH 85
[kldane
Atrazine
USEPA
MCL
1 NTU***
99.95% Reduction
0.015 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Influent
Average
10.3 NTU***
200,000 #/i.
015 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Influent Challenge
Concentration
1+_1NTU***
Mininmm 50,000 [
0.15 mg/i ++10%
0.15 mg/i ++10%
0.002 mg/i_+l 0%
0.009 mg/i &l 0%
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/i.
< 0.00002 mg/L
<0.002 mg/L
Ma,_lnu]ln
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
<0.002 mg/L
%Reducthm
Average Minimum
98.97% 98.61%
> 99.99% > 99.99%
> 99.33% > 99.33%
> 99.29% 97.86%
99.07% 98.75%
> 76.12% > 66.67%
Min. Requh'ed
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/i.
0.0002 mg/L
0.003 mg/i.
*Testedusinga flow rate of 0.5 gpm;pressureof 60psig pH of Z5+_0.5;temp. of 68° +_5°F (20° +_3°C)
** Measurementin Particles/ml.Particlesusedwere0.5-1 microns
*** NTU=NephelometricTurbidityunits
Operatino Specifications
[] Capacity: certified for up to 750 gallons (2,838 l); up to six months
[] Pressure requirement: 40-120 psi (2.8-8.2 bar)
[] Temperature: 33-100°F (0 ('_38°C)
[] Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requ#ements
[] Flush new cartridge at fitll flow for 3 minutes to purge out trapped air.
[] Replace cartridge when flow becomes too slow.
Special Notices
[] Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
[] This drinking water system must be maintained according to manttf_tcturer's instructions, inchtding replacement of filter
cartridges.
[] Do not use with water that is microbiologically unsafe or of tmknown quality without adequate disinfection before or
after the system. Systems cerdfied for cyst reduction may be used on disinfected water that may contain filterable cysts.
[] The contaminants or other sttbsmnces removed or reduced by this water treamlent system are not necessarily in your
water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was perfbrmed under standard laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with manttfitcturer's recommended procedures and guidelines.
System tested and certified by NSF ]mernatiolml against Standard 42 f )i the reductioll of
c}_lorille, taste and odor, particulate Class ] and Standard 53 tor the reductioll of cys[
lead, [Jlldane, Atrazine and turbidity
Malmtacmred fin': General Elecuic Compan), Louisville, KY 40225