C. Drying your room
Press MODE button on the control panel or remote control, the LED of DRY
operation lights up. The fan speed is unable to select. User should connect the
hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be
selected.
D. Sleep mode (this function can only be used with a remote
control)
The sleep mode can be activated when in cool mode.
In cool mode :
After 1 hour, the preset temperature increases by 34; after another hour,
the preset temperature will again increase by 34.
5.3.3 Timer Setting
1 hour−24 hours
:
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
5.3.4 Automatic Defrosting
At low room temperatures, frost may build up at the evaporator during the operation. The
unit will automatically start defrosting and the POWER LED will blink. The defrost
control sequence is as follows:
A. The ambient temperature sensor starts to sense the coil temperature after the
compressor works for 20 minutes. When the coil temperature is below or equal to 30
for 3 consecutive minutes, the compressor shuts down, the fan operates at high
speed, and the power light blinks; when the temperature is over or equal to 44, the
Press Timer key to
turn on the timer
function.
Press Timer key to
turn on the timer
function.
Press
Up/Down
repeatedly to set the
delay OFF time.
Press Up/Down
repeatedly to set the
delay ON time.
Press Up/Down repeatedly until the LED shows “00”.
Note: Pressing POWER will also exit the timer setting.