Turbofan G32D4/2C Full Size Tray Digital Gas Convection Ovens Double Stacked With Castor Base Stand

Installation Operation Manual - Page 16

For G32D4/2C.

PDF File Manual, 37 pages, Read Online | Download pdf file

G32D4/2C photo
Loading ...
Loading ...
Loading ...
Operation
14 14
NOTE: Adjustments made during cooking will not be saved to the program.
A. VIEWING STAGE NUMBER AND STAGE TIME REMAINING.
To view the Program and Stage numbers on the Upper Display, e.g. 3.1 = Program 3, Stage 1, and the Total Time Remaining in Stage
remaining on the Lower Display:
- Press Pkey during Program Cooking.
OR
- Turn Timer knob in either direction.
Upper Display will show Program and Stage, e.g.
Lower Display will show either,
- Total Time Remaining in Stage.
OR
- Total Elapsed Time of Stage (if Stage is set to InF’).
OR
- Core Probe Set Temp (if Stage is set to CP’).
OR
- Alternate between CPand Core Probe Set Temp (if presently in a Core Probe Stage).
Display will revert back to Overall Display after 5 seconds.
B. USING TEMPKNOB DURING PROGRAM COOKING.
VIEWING SET TEMPERATURE
Turn Tempknob (in either direction) to display Set Temperature of Current
Stage on Upper Display. Display will revert back to Overall Display after a
5-second delay.
ADJUSTING SET TEMPERATURE
Hold Tempknob in either direction for 3 seconds will enter Temp Edit Mode
where Tempknob can be used to temporarily adjust temperature for the current
stage. Controller will update the Temperature and exit Temp Edit Modeafter a
5-second delay.
C. USING TIMERKNOB DURING PROGRAM COOKING.
VIEWING STAGE NUMBER AND REMAINING TIME
Turn Timerknob (in either direction) to switch the display from Overall
(Program, Total Time remaining) to Current Stage-in-Progress (Stage, Stage
Time Remaining). Display will revert to Overall display after a 5-second delay.
ADJUSTING REMAINING TIME / ADJUSTING CORE PROBE SET TEMP
Hold the Timerknob in either direction for 3 seconds to enter Timer Edit Mode
where Timerknob can be used for temporary adjustment of either:
- Core Probe Set Temperature.
OR
- Stage Time remaining.
The controller will update the value and exit Timer Edit Modeafter a 5-second delay.
Time remaining can be adjusted between 0-180 minutes, but cannot be set to InFor
CP’.
Core Probe Set Temp can be set between 50-90°C (122-194°F).
NOTE: Any changes will only apply to the current stage. Any following stages will
revert to the programmed settings.
Here Oven Set Temperature has been
increased from 150 to 175°C (325 to 350°F).
Here Core Probe Temperature has been
increased from 54 to 75°C (129 - 167°F).
Loading ...