How to Convert the Range for use with LP/
Propane Gas
1. Convert the Pressure Regulator
To access the gas regulator, remove the storage drawer or warmer
drawer. If equipped with a storage drawer, open and remove the drawer
completely. For models equipped with a storage drawer or front panel,
remove the storage or front panel and skip steps a & b below. For models
equipped with warmer drawer, follow all the instructions below to remove
the warmer drawer.
a. _!_ Electrical Shock Hazard can occur and result in
serious injury or death. Disconnect electrical power to the range
before removing the warmer drawer for servicing.
b. Locate glide lever on each side of drawer, pull up on the left glide lever
and push down on the right glide lever (See Fig. 1).
c. Pull the drawer away from the range (See Fig. 2).
d. Remove the regulator access cover if equipped. Do not remove the
Pressure Regulator or allow it to turn.
e. Remove the dust protector from the cap. Using a 5/8" wrench,
unscrew the cap from the pressure regulator. Do not remove the
spring from the regulator.
f. Turn the cap over so the hollow end faces outward. Place the solid
end of the cap into the loop end of the dust protector (See Fig. 3).
g. Replace the cap on the regulator. The letters LP should be visible on
the exposed end of the cap. Snap the dust protector over the
regulator cap.
Pull up with finger
Left Glide
Fig. 3
Pressure
Front access to Regulator: Regulator
Open storage or warmer drawer, located at
or remove lower panel rear of
(on some models)
Fig. 2
Spring
Dust
Protector
Hollow End Solid End
Towards Towards
Regulator Regulator
for Natural Gas for LP/Propane Gas
Push down with finger
Fig. 1
Natural Gas Orifice to L.P. Orfice Conversion for each
size of burner
(A locations) 5,000 BTU Natural Gas
converts to 4,500 BTU L.P. Gas
Install (blue) marked orifice .68mm for L.P.
(B locations) 9,500 BTU Natural Gas
converts to 8,000 BTU L.P. Gas
Install (no color) marked orifice .89 mm for L.P.
(D locations) 12,000 BTU Natural Gas
converts to 10,000 BTU L.P.Gas
Install (green) marked orifice .95 mm for L.P.
(E locations) 14,000 BTU Natural Gas
converts to 11,000 BTU L.P. Gas
Install (red) marked orifice 1.01 mm for L.P.
(F locations) 16,000 BTU Natural Gas
converts to 14,000 BTU L.P.Gas
Install (black) marked orifice 1.99mm for L.P.
Fig. 4