4.5. DRAINAGE
Self- evaporating system
The self-evaporating system uses the collected water to cool the
condenser coils for better efficient performance. It is no need to empty
the drainage tank in cooling operation except in heating operation,
drying operation and high humidity conditions. The condensate water
evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation,
please connect the attached drain hose to the unit. Condensate water
can be automatically flow into a bucket or drain by gravity.
Switch off the unit before
operating.
Remove the plug of the water
outlet opening, and keep it in
safe area.
Securely and properly connect
the drain hose and make sure it
is not kinked and clear of
obstruction.
Place the outlet of hose over a
drain or bucket and ensure that
water could freely flow out of the
unit.
Do not submerge the end of hose
into water; otherwise it can cause
"Air Lock" in the hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the
drain hose downward toward the floor. It is appropriate that the
degree of inclination should exceed 20 degrees.
Straighten the hose to avoid a trap existing in the hose.
Continuous drain hose
(Inner diameter=16mm)
Remove the rubber
sealing plug.