Page 50
LA CORNUE
Installation Guide Centenaire
08NOTINSTAL100/USA-8
USA & CANADA
Stick on label
Stick the appropriate label on to the data badge to indicate the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the appliance is gas sound.
The gas pressure can be measured at the pressure test point on the appliance side on the manifold, near
the pressure regulator.
The light is located on the side at the top of the oven; it is
automatically switched on when the oven door is opened.
Please note: disconnect your stove before interfering with
the light to prevent any risk of an electrical shock and to
al low the appliance to cool down (if necessary).
Remove the protection glass and then unscrew the damaged
light.
Refit a new light and the protection glass.
Technical characteristics of the light:
- 25W - 230V - 240V
- 300°C - E14 base
Oven Light MAINTENANCE
Pressure
regulator
Pressure regulator
Pressure
test point
A
B
C
B
Cap
Natural Gas
Cap
LP Gas
5. REPLACING THE OVEN LIGHT
Your selection of LA CORNUE equipment is your assurance of quality and dependability that
reflects over 100 years of experience in manufacturing the finest gas cooking equipment.
You can always rely on your dealer and the Company to stand behind every product anywhere in
the U.S.A. and in Canada. For additional equipment, service and information contact your
dealer.