Easy-Kleen AS440GKGP 4000 PSI 4 GPM Gas Pressure Washer

Product Manual - Page 17

For AS440GKGP.

PDF File Manual, 32 pages, Read Online | Download pdf file

AS440GKGP photo
Loading ...
Loading ...
Loading ...
17
Cold Water Gas • Rev. 12/05/2017
QUICK DIAGNOSTICS AND SOLUTIONS GUIDE
PUMP
TYPE OF OIL
EK Pump
Hydraulic 68 (650ml)
GP Pump
30W SAE Non-Detergent
PROBLEM
POSSIBLE CAUSES
SOLUTIONS
PRESSURE
No pressure
or
Very low pressure
Metal in oil
- Examine oil in pump to see if there is metal in oil.
- If you find traces or pieces of metal, your pump
has damaged components.
Dirt in water
- Verify if there is dirt in nozzle tip or in valves in pump.
- If nozzle is plugged, clean or replace it.
- If valves in pump are clogged, clean valves.
- If valves in pump are damaged, replace valves.
Wrong nozzle size
- Make sure you have the right nozzle size. The black
nozzle will drop pressure in order to use chemical injector
and is only for soap or chemical. If you are not using soap,
use a different color.
Pressure too high
Wrong nozzle size
- Make sure you have the right nozzle size.
Unloader adjusted improperly
or damaged
- Check pressure of pump with a pressure gauge and adjust
to desired pressure.
- If you cannot reduce pressure, replace unloader.
Loading ...
Loading ...
Loading ...