Summit SCFF262GLH 30" Wide Upright All-Freezer

User Manual - Page 14

For SCFF262GLH.

PDF File Manual, 19 pages, Read Online | Download pdf file

SCFF262GLH photo
Loading ...
Loading ...
Loading ...
14
HOW TO CHANGE A PARAMETER VALUE
The hidden menu includes all the parameters of the instrument.
HOW TO ENTER THE HIDDEN MENU
1.
Enter the Programming mode by pressing the SET+DOWN keys for 3 seconds
(the “°Cor “°F” LED starts blinking).
2.
Release the keys, then again push the
SET+DOWN
keys for more than 7
seconds. The Pr2 label will be displayed immediately following the HY
parameter.
NOW YOU ARE IN THE HIDDEN MENU.
3.
Select the required parameter.
4.
Press the SET key to display its value
5.
Use UP or DOWN to change its value.
6.
Press
SET
to store the new value and move to the following
parameter.
To exit: Press SET+UP or wait for 15 seconds without pressing a key.
NOTE 1: If no parameter is present in Pr1, after 3 seconds the “noP
message is displayed, keep the keys pushed until the Pr2 message is
displayed.
NOTE 2: the set value is stored even when the procedure is halted by waiting
for the time-out to expire.
* WARNING: When the measurement unit is changed the SET point and the
values of the following parameters Hy, LS, US, OT, ALU, and ALL must be checked
and modified if necessary.
Loading ...
Loading ...
Loading ...