6-5 REFRIGERATING CYCLE
Troubleshooting Chart
CAUSE STATE OF STATE OF THE TEMPERATURE
THE SET EVAPORATOR OF THE REMARKS
COMPRESSOR
PARTIAL Freezer Low flowing sound of A little higher Refrigerant level is low due
LEAKAGE compartment and Refrigerant is heard and than ambient to a leak.
Refrigerator don't frost forms in inlet only temperature. * Normal cooling is possible
r-
m cool normally, when injecting of Refrigerant
"_" the regular amount.
_m WHOLE Freezer Flowing sound of refrigerant Equal to ambient No discharging of Refrigerant.
LEAKAGE compartment and is not heard and frost isn't temperature. Normal cooling is possible
Refrigerator don't formed, when injecting of Refrigerant
cool normally, the regular amount.
o PARTIAL Freeze Flowing sound of refrigerant A little higher ° Normal discharging of
_) CLOG compartment and is heard and frost forms than ambient refrigerant.
o Refrigerator don't in inlet only temperature. The capillary tube is faulty.
53
m cool normally.
-_ WHOLE Freezer Flowing sound of refrigerant Equal to ambient Normal discharging of
CLOG compartment and is not heard and frost isn't ! temperature. Refrigerant.
us Refrigeratordon'tcco[ formed.
MOISTURE Cooling operation Flowing sound of refrigerant Lower than Cooling operation restarts
CLOG stops periodically, is not heard and frost me_ts, ambient when heating the inlet of
temperature capillary tube.
o COMP- Freezer and Low flowing sound of A titlle higher ° Low pressure at high side
O _ RESSION Refrigerator refrigerant is heard and ambient of compressor due to low
"o -rl
::0m don't cool. frost forms in inlet only. temperature, refrigerant level.
m_
co-_
co_ NO COMPo No compressing Flowing sound of refrigerant Equal to ambient No pressure of high pressure
O m RESSION operation, is not heard and no frost, temperature, part in the compressor.
z
Leakage Detection
Observe discharging pointofrefdgerant whichmaybe in the oil dischargingpart inthe compressorandhole of evaporafor.
Check if compressor YES
runs or not.
Moisture Clog 1
Frostformed normally
Check if frost
forms or not in
Evaporator.
I
i Normal amount
Faulty
Compressor.
IClogged by dust.
Check
Compressor
I
Check ifoil
No frost _" leaks or not.
or forms
in inlet only
t Observe the discharged
amount of Refrigerant.
No or much amount
Inject refrigerant to compressor
and check coo] ng operation,
J
Frost formed normally
YES
>I Gas leakage. ]
(Check the leakage point)
-14-