3.
Select a Region. For the region sengs, see Draw Area .
4.
Set the rule.
Sensivity It stands for the percentage of the body part of an acceptable target that leaves
the pre-dened region.
Sensivity = 100 – S1/ST*100
S1 stands for the target body part that leaves the pre-dened region. ST stands
for the complete target body.
Example: If you set the value as 60, a target is possible to be counted as a
removed object only when 40 percent body part of the target leaves the region.
Threshold The threshold for the me of the objects removed from the region. If you set the
value as 10, alarm is triggered aer the object disappears from the region for
10s.
5.
Oponal: Repeat the above steps to set more regions.
6.
For the arming schedule sengs, see
Set Arming Schedule . For the linkage method sengs, see
Linkage Method Sengs .
7.
Click Save.
Note
The funcon is only supported by certain models. The actual display varies with the models.
Draw Area
This secon introduces the conguraon of area.
Steps
1.
Click Detecon Area.
2.
Click on the live view to draw the boundaries of the detecon region, and right click to complete
drawing.
3.
Click Save.
Note
Click Clear to clear the selected area.
Click Clear All to clear all pre-dened areas.
Set Size Filter
This part introduces the seng of size lter. Only the target whose size is between the minimum
value and maximum value is detected and triggers alarm.
Steps
1.
Click Max. Size, and drag the mouse in the live view to draw the maximum target size.