B. Install the Mounting Plate
Remove plastic bag, tape, and mounting plate
from the back of the indoor unit.
Place the mounting plate on the wall in the
desired location taking into account the
minimum clearances necessary for proper
operation.
Using a level, verify that the mounting plate is
horizontal and mark the screw locations.
Attach the mounting plate to the wall with the
supplied screws.
If not able to align all screw holes with studs, wall
anchors are supplied.
Be sure that the mounting plate has been
attached firmly and that applied weight is evenly
distributed by each screw. (At least one screw in
wall stud, others can use wall anchors.)
The piping for the indoor unit may be routed to
and from the unit in one of several directions:
left, left rear, right, right rear, or right below. See
Illustration on page 7.
Knockouts are provided on the unit case for Left,
Right, and Right Below usage.
C. Install the Tubing
Measure and mark the location where the piping
hole is to be drilled.
If pipe location will be on the left side of the unit,
follow these steps to move the drain pipe.
1. Remove the stopper in the left drain hole and
knockout the molded plug inside the port.
2. Transfer the corrugate drain hose from the right
side to the left side.
3. Insert stopper into right side drain port. Using
soap as a lubricant and a small screwdriver will
allow for easier seating of the stopper.
Drill the lineset hole using a 2 1/4” hole saw.
Angle the drill with a downward pitch to the
outside wall so that the outside wall hole will be
at least a ¼” lower than the inside hole. This
allows for proper drainage of condensate.
Install the lineset hole flange at the hole opening
on the inside wall.
NOTE: The flange is prescored. It may be
necessary to modify the flange to fit properly
behind the wall unit housing.
Installation Instructions
Step 2 - Installation of the Indoor Unit
A. Select the Indoor location:
Do not allow any heat or steam near the unit.
Select a location where there are no obstacles in
front of the unit.
Make sure that condensate drainage can be
conveniently routed away.
Do not install near a doorway.
Ensure that the space around the left and right
of the unit is more than 4”. The unit should be
installed as high on the wall as possible but allow a
minimum of 4” from the ceiling.
Use a stud finder to locate and mark stud locations
for mounting and to prevent unnecessary damage
to the wall.
Install in a location that is strong enough to
withstand the full weight and vibration of the unit.
Leave enough space to allow access for routine
maintenance.
Select a location that gives easy access to
removing and cleaning air filters.
Install in a location that is 3 ft. or more away from
other electrical appliances, such as televisions and
audio devices.