Greenworks 01-0002516807UK Optimow S Robot Lawnmower

User Manual - Page 7

For 01-0002516807UK.

PDF File Manual, 74 pages, Read Online | Download pdf file

01-0002516807UK photo
Loading ...
Loading ...
Loading ...
GREENWORKSTOOLS.EU
7
EN
Version 2 - 2021.10.25
Troubleshooting
This section also presents some symptoms that can guide you if the mower does not work as expected.
INDICATOR LEDS ON MOWER
BREAKS IN BOUNDARY WIRE AND GUIDE WIRE
Breaks in the boundary wire and guide wire (if installed) are usually the result of unintentional physical damage.
Inspect the entire boundary wire from the charging station and back.
Inspect the guide wire (if installed) from the charging station to the splice into the boundary wire.
Inspect that all the couplings have been properly squeezed to make connections.
LED STATUS MEANING ACTION
1. Operating
(Green)
Flashing Recovery mode Place the robot in charging station with a
mobile with the Greenworks tools App close
to the mower for software update of mower.
This can take up to 1 hour until the green LED
to stop flashing. If LED doesn’t stop flash then
restart the robot outside the CS and try again.
On Mower in operation mode (charging, parked in Charging
station, paused, mowing or searching)
Off Mower stopped with Stop button on mower, safety key in
Disabled position, mower in error state or mower waiting
for PIN code.
2. Connectivity
(Blue)
Flashing Mower not ready for Bluetooth connection If mower stopped with error the mower need
to be restarted with the Start button to allow
Bluetooth connection again
On Mower ready for Bluetooth connection with Mobile App
Off Mower not in ”Power on mode
3. Security
(Yellow)
Flashing PIN code authorization required ... via Mobile App.
Off No pin required No action required
4. Error
(Red)
Flashing Mower stopped with error Check the reason for the error and then restart
by pressing the Start button on the mower.