9
Installation
3. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
4. Connect gas supply to appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
5. Check gas operating pressure is as shown in ‘Specifications’ section.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in 'Specifications' section.
NOTE: Operating pressure to be measured at manifold test
point and with burners operating at ‘High Flame’
setting.
8. Verify operating pressure remains correct.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE
CARRIED OUT BY AN AUTHORISED PERSON.
Each appliance should be connected to an adequately protected
power supply and isolation switch mounted adjacent to, but not
behind appliance. This switch must be clearly marked and readily
accessible in case of fire.
1. Check electricity supply is correct as shown on Rating Plate located on front right hand corner of
bottom sill.
2. Electric fan motor and all corresponding electrical switches are connected through a 2m, 10 Amp flex
located at rear of oven.
3. For immediate electrical supply, simply fit a plug to flex (if a plug is not already fitted) and plug lead
into a properly earthed, 3 pin socket.
Commissioning
1. Before leaving the new installation;
a. Check the following functions in accordance with operating instructions specified in 'Operation'
section of this manual.
 Light the Target Top Pilot Burner.
 Light the Target Top Main Burner.
 Light the Oven Pilot and Main Burners.
 Check the Oven Main Burner Thermostat operation.
 Check the Low Fire Burner operation for Target Top and Oven.
 Check the High Fire Burner operation for Target Top and Oven.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2. This manual must be kept by owner for future reference, and a record of
Date of Purchase,
Date
of Installation
and
Serial Number of Appliance
recorded and kept with this manual. (These
details can be found on Rating Plate located on front right hand corner of bottom sill.
Refer to 'Gas Connection' section).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut off gas
supply and contact supplier of this appliance.
Fig 1
Low Fire
Adjustment
Screw
Manifold
Pressure Test
Point
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.