Dewalt DXCMLA1983054 Portable Vertical Electric Air Compressor 30 gal

Instructional Manual - Page 15

For DXCMLA1983054.

PDF File Manual, 88 pages, Read Online | Download pdf file

DXCMLA1983054 photo
Loading ...
Loading ...
Loading ...
15
English
1. Move Auto/Off switch to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
2. Pull the regulator knob out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push
knob in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
MAINTENANCE
Maintenance Chart
Procedure
Daily
Weekly
Monthly
1 year
or 100
Hours
See tank
warning
label
Check safety valve
X
Inspect air filter
X
+
Drain air tank
X
OPEN
CLOSE
FIG. 3
OFF
AUTO
Loading ...
Loading ...
Loading ...