18
English
3) supply 5 – 10 drops of metabo HPT pneumatic
tool lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor
tank to drain any moisture.
ADJUSTING THE NAILING DEPTH
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(regulator is installed and working properly), and
2) the Nailer is always held rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1
DISCONNECT AIR HOSE FROM NAILER.
Adjuster
Disconnect air hose
15
2
If nails are driven too deep, turn the adjuster to the
shallow side.
2
Too Deep
Flush
Turn Adjuster
If nails are driven too shallow, turn the adjuster to the deep
side.
Turn Adjuster
Flush
2
Too Shallow
3
Stop turning the adjuster when a suitable position is
reached for a nailing test.
4
Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5
DISCONNECT AIR HOSE FROM NAILER.
6
Choose a suitable position for the adjuster.
USING THE NOSE CAP
WARNING
Disconnect the air hose from the nailer
before attaching or removing the nose cap.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1
DISCONNECT AIR HOSE FROM NAILER.
2
Put the nose cap to the toe of the push lever.
NOTE:
The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
1
Push Lever
Nose
Hole
Protrusion
(Inward)
Do not connect
air hose
Nose Cap
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Nose cap
Screwdriver
Push lever
000BookNR90AD(S1)metabo.indb18000BookNR90AD(S1)metabo.indb182018/03/1916:14:442018/03/1916:14:44