Maytag MLE24PDAGW2 27 Inch 14.8 cu. ft. Commercial Stacked Electric Dryer

Installation Instructions - Page 11

For MLE24PDAGW2. Also, The document are for others Maytag models: MLE24PD, MLE24PN

PDF File Manual, 44 pages, Read Online | Download pdf file

MLE24PDAGW2 photo
Loading ...
Loading ...
Loading ...
11
1. Disconnect power.
2. Remove hold-down screw and the terminal block cover.
3. Assemble 3/4" (19 mm) UL-listed strain relief (UL marking
on strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Install power supply cord through the
strain relief.
4. Complete installation following instructions for your type of
electrical connection:
•Four-wire(recommendedmethod)
•Three-wire(iffour-wireisnotavailable)
11
B
C
A
A. Strain relief clamp sections
B. Dryer cabinet
C. Strain relief screws
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground
wire from the external ground conductor
screw. Fasten under center terminal block
screw.
7. Connect the ground wireof the power
supply cord to the external ground
conductor screw. Tighten screw.
8. Connect the neutral wire (white or center)
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
9. Connect the other wires to outer terminal
block screws. Tighten screws.
10. Tighten strain relief screws.
11. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
Four-wire power supply cord must have four, No. 10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The fourth wire (ground conductor) must be identified
by a green cover and the neutral conductor by a white cover.
B
D
C
G
F
E
A
A. Spade terminals
with upturned ends
B. Neutral
C.
3/4" (19 mm)
UL-listed strain relief
D. Neutral (white)
E. Ring terminals
F. Ground wire
G. Ground prong
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Strain relief screw
F. Neutral (center wire)
G. Ground wire
Power Supply Cord,
Four-wire electrical connection:
C
B
A
F
G
E
D
Power Supply Cord Method – U.S. Only
If local codes do not permit the connection of a neutral ground
wire to the neutral wire, see “Optional 3-wire connection”
section.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral
is prohibited for (1) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductors.
C
D
B
A
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw