7ENGLISH
Switch action
WARNING: Before installing the battery car-
tridge into the tool, always check to see that the
switch trigger actuates properly and returns to
the "OFF" position when released.
WARNING: Do not attach a tape or such to
keep the switch trigger in the "ON" position.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
1
1. Switch trigger
Pressure gauge
3
4
5
2
6
7
8
1
9
1Overheat warning icon
2Ination mode
3[-] button
4[M] button
5[+] button
6Ination progress indicator
7Current pressure value
8Target pressure value
9Pressure value unit
If the object to be inated is connected to the tool, the
current pressure value of the object is displayed on the
pressure gauge when you turn on the tool. If nothing is
connected to the tool, the pressure gauge displays "0".
The pressure gauge also displays the target pressure
value, pressure value unit, and ination mode. They are
the same as the last time.
When you start ination, the ination progress indicator
is displayed. The ination completes when the ination
progress indicator comes to the right end.
Setting the target pressure value
Press the [M] button, and select the pressure value unit.
The pressure value unit is changed each time you press
the [M] button. You can select one of the three units:
PSI, BAR, or KPA.
To increase the target pressure value, press the [+] but-
ton. To decrease the target pressure value, press the [-]
button. You can set the target pressure value between
35 kPa (5 PSI) and 1,100 kPa (160 PSI).
Setting the ination mode
Press the [M] button for 3 seconds. The ination mode
is changed each time you press and hold the [M] button.
You can select one of the three modes as follows.
Mode Display Purpose Adjustable
pressure
range
Ball To inate
balls
35 to 110 kPa
(5 to 16 PSI)
Low speed To inate
objects in low
speed
35 to 1,100
kPa
(5 to 160 PSI)
High speed To inate
objects in
high speed
NOTE: Be sure to select the ball mode when you
inate a ball using a sport ball needle. If other mode is
selected, the ination cannot be performed properly.
NOTE: Be sure to select the low speed mode when
you inate an object using an English valve adapter. If
other mode is selected, the ination cannot be per-
formed properly.
Loading ...
Loading ...
Loading ...