16
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
The wet/dry vacuum will not
operate.
No power supply.
Check the power supply, cord,
breakers and fuses.
Faulty power cord.
Unplug and check the power
cord. If damaged, have it
repaired by a professional.
Collection tank is full. Empty the collection tank.
Switch in the wrong position.
Press the ON ‘I’ button on the
power head.
The dust comes out from
the motor cover.
The cartridge lter is missing or
damaged.
Attach or replace the cartridge
lter.
Vacuum has been used to collect
ne dust, such as dry wall dust,
replace soot, or ash, without a ne
dust lter.
Install the correct cartridge lter.
Reduced efciency and
motor/speed vibration.
There are blockages in the nozzle,
hose, or the collection tank inlets.
Unplug and check nozzle, hose
and collection tank inlets for
blockages.
Cartridge lter is clogged by ne
dust.
Take off the lter and clean it or
install a new cartridge lter.
Filter cleaning operation
fails.
Air leakage from the end of the
hose nozzle.
Ensure that the end of the hose
nozzle is completely sealed.
The drain cap is not tightened.
Ret the drain cap and tighten it
properly.
The cartridge lter needs to be
replaced.
Replace with a new cartridge
lter.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.