Function and Features
Copyright ©ITECH Electronic Co., Ltd. 18
KNOB (ON)
LOCK
Lock the rotary knob function
ON
Unlock the rotary knob function
Ext-C
OFF
Disable external signal control function
ANA
Enable external analog control function
DIGIT
Enable external digital control function
TRIG (MANUAL)
MANU
Local keyboard trigger
BUS
External trigger
MEM (GROUP1)
GRP1-8
Save and recall operation
ADC SPEED
SLOW
AD speed is low speed
MID
AD speed is middle speed
FAST
AD speed is high speed
METER RETURN
WAIT 5
S
In the voltage/current setting state (or the LOCK state to
view the set value), if there is no operation in 5S, it will
automatically return to the measurement state.
NO
It does not automatically return to the measurement
state.
TIMER SET
OFF
Close the timer function
ON
Open the timer operation, the time can be set within
0.1-99999.9s
RESET
NO
keep the original setting
YES
restore the factory setting
EXIT
Quit the menu setting
LIST SET
LIST STATE
OFF
Close list test function
ON
Open list test function
LIST LOAD
Recall the saved list file(FILE0-FILE9)
LIST EDIT
TIME
(SEC)
SEC
second
MIN
minute
VSET
Setup the single step voltage
ISET
Setup the single step current
SEC
Setup single step delay time(0.1-9999)
NEXT
(YES)
YES
continue the edit of next step
NO
End up the list file edit
REPET
1-65535
Set the cycle time of list file
SAVE
NO
Do not save the current list file
FILE0-FILE9
Save the list file to appointed document
EXIT
Quit the system menu
POWER
INFO
MODEL
Unit model
VER
The software version
SN-1
The first six number of SN
SN-2
The middle six number of SN
SN-3
The last six number of SN
EXIT
Quit the information menu