MAKE ELECTRICAL CONNECTION
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
A.White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable
F. UL listed or CBA approved
I/2" strain relief
G. Green ground screw
C D.
A ......_ E
2. Use UL listed wire connectors and connect white wires
(A) together.
3. Use UL listed wire connectors and connect black wires
(B) together.
INSTALL RANGE HOOD
(Recirculating version)
1.Lift the range hood up under cabinet and determine
final location by centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood (See slots
dimensions on page 6). Set range hood aside on a
covered surface. A
A
Keyholeslot
2.Use 1//, (3 mm) drill bit and drill 4 pilot holes as shown.
NOTE: Make the drill holes on the thin area of the slot.
A. Drill pilot hole
Fire Hazard
Electrically ground the blower. Use copper wire.
Connect ground wire to green ground screw in
terminal box. Failure to do so can result in death,
fire, or electrical shock.
4. Connect green (or bare) ground wire from power supply
to green ground screw in terminal box and securelytighten.
5. Install terminal box cover.
6. Install the 75W (max.) Incandescent light bulb. See
"Replacing the Incandescent Light Bulb" in the "Range
Hood Care" section.
7. Reconnect powec
Complete Installation
1.Replace grease filter if removed. See the "Range Hood
Care" section.
2.Check the operation of the range hood fan and light.
See "Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
To get the most efficient use from your new
range hood, read the "Range Hood Use" section.
12
3.Install the 4 - .45 cmx 1.3 cm mounting screws in
pilot holes. Leave about 1/4"(6.4 mm) space between
screw heads and cabinet to slide range hood into place.
\\\\\\\\\\ _ 114"
__ (6.4 mm)
Power Supply Cable Installation
1.For direct wire installations, run the home power
supply cable according to the National Electric Code
or CSAstandards and local codes and ordinances.
There must be enough wiring from the fused disconnect
(or circuit breaker) box to make the connection in the
hood electrical terminal box.
Do not reconnect power until the installation is
complete.
2.Remove the screw from the --____bt_)![ _,,I
terminal box cover.
Remove terminal box cover .............................
and set aside.
A. Terminal box cover II
B. Screw