Operation
10
LED display
Displays set temperature, in either °C or °F
.
Displays auto-timer settings (if any)
When unit is in DR
Y
or F
AN modes, displays
currentroom temperature.
Displays error codes and protection codes:
E1: Room temperature sensor error
E2: Evaporator temperature sensor error
E3: Condenser temperature sensor error
E4: Display panel communication error
P1: Bottom tray is full. Connect the drain hose
to drain and empty the bottom tray
.
Note: When one of the above malfunction
occurs, turn offthe unit and check for any
obstructions. Restart the unit,
if the error
persists, turn of
f unit and unplug power cord.
Contact Sunpentown customer service at
800-330-0388.
CAUTION! If unit is stopped or powered of
f unexpectedly
,
there will be a 3-minute delay before unit will start up
again.
This is to protect the compressor
. Unit will
automatically resume after 3 minutes.
Operation Instructions
COOL
operation
- Press the MODE button until COOL
indicator lights up.
- Press the + or - button to set desired room temperature.
T
emperature range is between 62°F~86°F (17°C~30°C).
- Press the F
AN button to choose desired fan speed.
HEAT operation ((heating models only)
- Press the MODE button until HEAT indicator lights up.
- Press the + or - button to set desired room temperature.
Temperature range is between 62°F~86°F (17°C~30°C).
- Press the FAN button to choose desired fan speed.
F
AN operation
- Press the MODE button until F
AN indicator illuminates.
- Press the F
AN button to select desired fan speed.
-
The temperature cannot be adjusted.
- Exhaust hose connection is not needed.
DRY
(dehumidify) operation
- Press the MODE button until the DR
Y
indicator
light illuminates.
- Under this mode, fan speed cannot be selected and
temperature cannot be set. The fan operates at LOW
.
- Keep windows and doors closed for the best
dehumidifying ef
fect.
- Do not connect exhaust hose fixture to window
.
AUT
O operation
- When the unit is set in
AUT
O mode, it will automatically
select cooling or fan mode, depending on set temperature
and ambient room temperature.
-
The air conditioner will operate in the appropriate mode
based on the set temperature.
- Under AUT
O mode, fan speed cannot be set.
Operating Temperature Range
Cool
17-35°C (62-95°F)
Dry
Heat
(heating models only)
13-35°C (55-95°F)
5-30°C (41-86°F)
Mode
Temperature Range
Loading ...