V-Tac VT-6606 6kW On/Off Grid Hybrid Solar Inverter

INSTRUCTION MANUAL - Page 30

For VT-6606.

PDF File Manual, 45 pages, Read Online | Download pdf file

VT-6606 photo
Loading ...
Loading ...
Loading ...
5.5.4.2 EPS en able
Interface
Description
EPS ENABLE
1:DISABLE
2:ENABLE
When the Grid and PV are powered off, Enable the battery to
supply power to the load, default option is enable.
5.5.4.3 Battery wak e- up
Interface
Description
WAKE-UP EN
1:DISABLE
2:ENABLE
When the battery is low and the battery relay has been
disconnected, the inverter will send instructions to the battery
forcibly sucking relay by BMS, and the inverter will charge.
The default option is disabled. (
Partial battery support)
5.5.4.4 REM OTE CT RL
Interface
Description
REMOTE CTRL
1:DISABLE
2:ENABLE
Remote control the inverter on or off.
(
Subsequent support…)
The default option is disabled.
5.5.4.5 STAR T DEL AY
Interface
Description
START-UP DELAY
INPUT: 60
UNIT: SEC
The input value ranges from 20 to 300, which varies with dierent
standards.
5.5.4.6 PV I N PUT MO DE
Interface
Description
INPUT MODE
1.INDEPENDENT
2.PARALLEL
3.CV
Setup of PV Input mode.
The factory setting by default is Independent, When parallel input
is set to be stand-alone mode, PV power will be imbalanced.