Smeg SSA91MABL2 Cooker with Gas Hob 90x60 cm

User manual EN - Page 23

For SSA91MABL2.

PDF File Manual, 27 pages, Read Online | Download pdf file

SSA91MABL2 photo
Loading ...
Loading ...
Loading ...
INSTALLATION - 2591477A887/B
e
town gas
Light the burner and turn it to the minimum
position. Extract the gas cock knob and turn the
adjustment screw next to the gas cock spindle
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner flame is
stable. Turn the knob rapidly from the maximum
to the minimum setting: The flame should not go
out. Repeat the operation on all gas cocks.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the cock
spindle clockwise all the way.
Lubricating the gas cocks
Over time the gas cocks may become difficult to
turn and get blocked. Clean them internally and
replace the lubrication grease.
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Positioning
Depending on the type of installation, this
appliance belongs to classes:
The appliance can be placed against walls that
are higher than the work surface, at a minimum
distance of X mm from the side of the appliance.
Any wall units installed above the appliance’s
worktop must be positioned at least Y mm from
it.
Following adjustment to a gas other
than the one originally set in the factory,
replace the gas setting label on the
appliance with the one corresponding
to the new gas. The label is inserted
inside the nozzle pack (where present).
Lubrication of the gas cocks should be
performed by a specialised technician.
Natural Gas G20 - 20 mbar AUX SR R UR
Rated heating capacity (kW)
1.0 1.8 2.9 4.0
Nozzle diameter (1/100 mm)
72 94 115 145
Pre-chamber (printed on nozzle)
(X) (Y) (Y) (Z)
Reduced flow rate (W)
400 500 800 1600
LPG G30/31 - 30/37 mbar AUX SR R UR
Rated heating capacity (kW)
1.01.752.9 4.0
Nozzle diameter (1/100 mm)
50 65 85 102
Pre-chamber (printed on nozzle)
---
Reduced flow rate (W)
400 500 800 1600
Rated flow rate G30 (g/h)
73 127 254 291
Rated flow rate G31 (g/h)
71 125 250 286
See General safety instructions.
Class 1 Free-standing
Class 2 - subclass 1 Built-in
X 150 mm
Y 750 mm
Loading ...
Loading ...
Loading ...