Napoleon LV38N1 Vector Series Direct Vent Natural Gas Fireplace

User Manual - Page 43

For LV38N1.

PDF File Manual, 140 pages, Read Online | Download pdf file

LV38N1 photo
Loading ...
Loading ...
Loading ...
EN
W415-1709 / A / 07.27.17
43
finish framing - after appliance installation
Ceiling
single-sided recessed
Shaded components (finish framing) must be
non-combustible materials
Finish framing must be built after the appliance has
been placed in its final position and venting
connected.
note:
Ref LV38-1 LV50-2 LV62 LV74
K
39 15/16” (101.4cm) 39 15/16” (101.4cm) 39 15/16” (101.4cm) 39 15/16” (101.4cm)
E
20 1/8” (51.1cm) 20 1/8” (51.1cm) 20 1/8” (51.1cm) 20 1/8” (51.1cm)
F
53 13/16” (136.7cm) 65 13/16” (167.2cm) 77 13/16” (197.6cm) 89 13/16” (228.1cm)
J
Optional - Appliance does not need to be elevated above floor
L
73” (185.4cm) 73” (185.4cm) 91” (231.1cm) 91” (231.1cm)
M*
3” (76mm) 3” (76mm) 3” (76mm) 3” (76mm)
Insulation
Drywall
*Can only be increased to 4” max by building a protrusion.
K
E
F
J
L
M*
minimum framing
This configuration also requires recess
area to use non-combustible facing due
to close proximity to vent.
note:
Although the minimum enclosure
height for the LV series is 73”,
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.