INSTRUCTIONS FOR USE
Follow these instructions carefully to avoid seriously damaging your pizza oven and causing
injury to yourself and to property.
1. Assemble the pizza oven by following the assembly instructions carefully.
2. Connect the gas hose to the pizza oven. Connect the regulator to the hose.
3. Connect the regulator to the cylinder valve following the regulator instructions supplied with
the regulator.
4. Turn the control knobs to the ‘OFF’ position before turning on the gas supply to the appliance.
5. Operate the regulator in accordance with the instructions supplied with the regulator.
LIGHTING THE PIZZA OVEN
1. Connect the gas cylinder to the pizza oven following the instructions supplied with the
regulator.
2. Turn the control knob to the ‘OFF’ position.
3. Turn ‘ON’ the gas supply at the cylinder or regulator switch following the regulator connection
and operating instructions. Check the cylinder to regulator connection and hose to pizza
oven hose inlet connection for leakage using soapy water. Any leakage will show as bubbles
in the area of the leak. If leak is found, do not use the pizza oven. Consult your gas or pizza
oven supplier for advice.
4. To light the burner, push down the control knob and keep pressing whilst turning anti-
clockwise to the “Full rate” position and press the ignition button waiting for 4 seconds. This
will light the burner. Check that the burner is alight. If the burner has not lit, repeat this
process.
5. If the burner has not lit after two attempts, turn ‘OFF’ the gas tap and wait 5 minutes before
retrying the ignition sequence.
6. When the burner has lit, the burner rate can be adjusted by push down and turn the knob
anti-clockwise to any position between the full and low rate position.
7. To turn ‘OFF’ the pizza oven, turn the cylinder valve handle or regulator switch to the ‘OFF’
position by following the regulator instructions. Once the burners have extinguished turn all
the control knobs to the ‘OFF’ position.
Warning: If the burner fails to ignite, turn the control knob off (clockwise) and also turn
the cylinder valve off. Wait five minutes before attempting to relight with ignition
sequence.
After use, close the gas supply by either turning ‘OFF’ the switch on the regulator or turning
‘OFF’ the cylinder valve.
In the event of light back whilst the appliance is in use. Turn the control, cylinder valve and
regulator switch to the ‘OFF’ position. Wait 5 minutes before attempting to relight the appliance.
If the problem persists after relighting, consult your gas dealer, or the store where you