Rinnai 17 HotoElectricStorageWaterHeaterOIM
ELECTRICAL SUPPLY
WARNING
Mustbeinstalled,maintainedandremovedbyauthorisedpersonsinaccordancewithAS/NZS
3000 and all other relevant local regulations and municipal building codes including OH&S
requirements.
Ensureelectricwiringisinstalledproperly.Improperinstallationmaycausemalfunction,re,or
electric shock.
Theunitmustbeearthedfollowinglocalelectricalcodes.
AwaterheaterNOTttedwithapowercord&plugMUSThavetheheatingelementconnectedtoanindependent,
fused,AC240V50Hzpowersupplywithanisolatingswitchinstalledattheswitchboard,whichshalle󰀨ectively
isolateallactivesupplyconductorsfromthecircuitandmeansfordisconnectionmustbeincorporatedinthexed
wiringinaccordancewiththewiringrules.
Ensurethepremiseswiringtothesystemiscapableofwithstandingthesystemelectricalload(refertoSpecications
-Table1forelectricalloaddetails).
ThepowersupplytoasingleelementmodelcanbeO󰀨-Peak(overnight),ExtendedO󰀨-Peak(overnightandday),
orContinuous(day).
The power supply to a twin element model should be O󰀨-Peak (overnight) to bottom heating element and
Continuoustothetopheatingelement.
Checktheavailabletari󰀨swiththelocalelectricitysupplier.TheO󰀨-Peak(overnight)isusuallythemosteconomical
forthecustomer.
Electrical Connections
WARNING
ThewaterheaterMUST BElledwithwaterpriortoconnectiontothepowersupply.
WARNING
ElectricalconnectionMUST BEcarriedoutbyaqualiedpersonandinaccordancewithAS/NZS
3000 'Wiring Rules' and local authority requirements
Disconnect all power prior to installation and commissioning. This appliance is designed for
singlephase240Volts,ACmainselectricaloperation.
All electrical connections MUST BEmadebyanauthorisedpersonandmustcomplywithall
localelectricalsupplyregulationsandAS/NZS3000.
NOTE
Thepremiseswiringtotheheatermustbecapableofwithstandingtheapplianceload.
Electricalaccessisviaa20mmholebeneaththeelementcoverformountingwithanapprovedweatherproof
electricalconduitnipple.Forentrytotheelementcoverremovethetwoxingscrews.
ConnectallACTIVEandNEUTRALwiresinaccordancewiththewiringdiagramwhichisalsoincludedattherear
oftheelementaccesscover.EnsuretheincomingEARTHwireissecurelyxedtotheearthpostprovidedonthe
heatercase.Inspectandensurethatallwiringlinksaresecurepriortoxingtheaccesscoverandturningthe
POWERON.
ToensuretheOver-temperatureandEnergyCut-outisset,pressthe(red)'reset'buttonontheThermostat.
Isolate all
sources of supply
prior to servicing
INSTALLATION