Rinnai 15 HotoElectricStorageWaterHeaterOIM
THERMOSTAT SETTING
Thethermostatsettingcanbeadjustedbetween60°Cand70°C.Ithasbeenfactorypre-setto70°C.
WARNING
Thisappliancemaydeliverwaterathightemperature.RefertothePlumbingCodeofAustralia
(PCA), local requirements and installation instructions to determine if additional delivery
temperature control is required.
WARNING
ThethermostatsettingsMUST ONLYbeadjustedbyaqualiedperson.
REDUCING THE RISK OF SCALDING
Thiswaterheatercandeliverwaterattemperatureswhichcancausescalding.Children,disabledandtheelderly
areatthehighestriskorbeingscalded.
Local regulatory requirements and the requirements of AS/NZS 3500.4 MUST BE considered regarding
temperaturelimitationsofhotwater deliveredtoareasusedprimarilyforpersonalhygienesuch asbathrooms
andensuites.Thedeliverytemperaturemaybelimitedto45°Cforearlychildhoodcentres,primaryandsecondary
schoolsandnursinghomesorsimilarfacilitiesfortheyoung,aged,sickorpeoplewithdisabilitiesand50°Cforall
otherbuildings.ThesetemperatureswillreducetheriskofscaldinjuryandcanbeachievedbytheuseofaTLD,
forexampleathermostaticmixingvalveortemperingvalve.
RinnairecommendthatanapprovedTLDisttedintothehotwaterpipeworkfromthewaterheatertoareasused
primarilyforpersonalhygienesuchasbathroomsandensuitestoreducetheriskofscalding.
Refertotheinstallationcongurations"HotWaterPlumbingSystemExample-WithTLD"onpage12and"Hot
WaterPlumbingSystemExample/Flow&ReturnPipeWork-WithTLD"onpage13.
PLUMBING CONNECTIONS
Connections to the water heater
RefertoSpecicationsfortheplumbingconnectionsizesandlocation(Table1)andthespeciedpressureratings
ofvalves(Table2).Referalsotothediagramsunder“InstallationCongurations”.
WARNING
ValveswithpressureratingsotherthanspeciedMUST NOTbeused.
Anisolationvalveandnon-returnvalveMUSTBEttedinthecoldwatersupplytothewaterheatersothewater
heatercanbeisolated.Combinationisolationandnon-returnvalvesuchas'Duo'or'Trio'valvesaresuitablefor
thispurpose.
IsolationvalvesMUSTNOTbetteddirectlytotheappliance.Usedisconnectionunionsbetweenthewaterheater
andthevalvestoallowthewaterheatertobedisconnectedfrompipeworkatalaterdate.
Purgepipework toremove swarf andother foreign matterbefore nalconnection to thewater heater toavoid
damagetothewaterheater.
IfolivecompressionttingsareusedforconnectionstheolivesMUSTBEmetallicsuchasbrassorcopper.Only
approvedthreadsealingtapeorsealantshouldbeused.
Water Pipes
Pipesizingshouldbecarriedoutbypersonscompetenttodosoforeachindividualinstallationinaccordancewith
localregulatoryrequirementsandtakeintoconsiderationthespecicationsofthewaterheater.
ThecoldsupplypipetoandhotwaterpipefromthewaterheaterMUSTBEinsulatedinaccordancewithlocal
regulatoryrequirementsandAS/NZS3500.4tooptimiseperformanceandenergye󰀩ciency.InsulationMUSTBE
weatherproofandUVresistantifexposed.
Thehotwaterpipefromtheoutletofthewaterheatershouldalsobeconguredintheshapeofa“heattrap”toaid
energye󰀩ciencyinaccordancewithlocalregulatoryrequirementsandAS/NZS3500.4.
Topreventdamagetothewaterheaterwhenattachingpipeclipsorsaddlestothejacket,itisrecommendedthat
selfdrillingscrewswithamaximumlengthof12mm areused.Ifdrillingisrequiredtakeextreme care NOT to
penetratetheinnercylinder.DamagetotheinnercylinderisNOTcoveredunderwarranty.