Performance Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/55.*
200% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent
MCL Challenge Concentration
Chlorine - 2.0mg/L+ 10%
T&O - -
Particulate** - _>10,000particles/mL
Influent
Average
1,96 mg/L
6,400,000#/mL
Effluent
Average Maximum
0.06mg/L 0.11mg/L
58,833#/mL 150,000#/mL
% Reduction
Average Minimum
96.77% 94.74%
99.14% 97.97%
Parameter
Turbidity
Cysts
Asbestos
Leadat pH65
Leadat pH8.5
Nercurgat pH6.5
Nercurgat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
USEPA
MCL
05 NTU
_>99.95%Reduction
_>99%Reduction
0,015mg/L
0.015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11+ 1 NTU***
Ninimum50,000L
107to 108fibers/L;> 10pm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
Influent
Average
10.5 NTU
118,750 #/L
57 MF/L
0.1567 mg/L
0.1433 mg/L
0.0059 mg/L
0.0057 mg/L
0.0367 mg/L
0.0020 mg/L
0.2033 mg/L
0.0160 mg/L
0.0145 mg/L
0.0830 mg/L
0.2283 mg/L
Effluent
Average
0.14NTU
< I#/L
0.996MF/L
< 0.001mg/L
< 0.001mg/L
0.000350mg/L
0.000325mg!L
0.00023mg/L
<0.00002mg/L
0.00337mg/L
0.00100mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
Maximum
0.28NTU
4#/L
< 1 MF/L
< 0,001mg/L
< 0,001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002mg/L
0.011000mg/L
0.001000mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
% Reduction
Average Minimum
98.54% 97.20%
> 99.99% > 99.99%
99.60% 99.39%
99.36% 99.29%
99.30% 99.29%
94.70% 87.50%
93.20% 89.29%
99,34% 98.67%
99.00% 98.95%
98.32% 94.50%
93.44% 91.67%
9651% 95.83%
98.78% 98.65%
99.78% 99.77%
Atrazine 0.003mg/L 0.009 mg/L±10% 0.0087 mg/L < 0.0005 mg/L < 0.0005 mg/L 94.22% 93.33%
Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-ff microns
*** NTU=Nephelometric Turbidity units
Min. Required
Reduction
> 50%
_>85%
Min. Required
Reduction
0.5NTU
_>99.95%
_>99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.04mg/L
0.075mg/L
0.003mg/L
Operating Specifications
[] Capacity: certified for up to ]00 gallons (1115 I); up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
[] Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
[] Temperature: ]]-IO0°F (0.6-]8°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
[] Flush new cartridge at full flow for ] minutes to purge out trapped air.
[] Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
[] Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
[] This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
[] Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
[] The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY 40225