Locang Your Outdoor Appliance
It is important when selecng a locaon for your appliance to ensure clearances to adjacent combusbles
are met. This appliance is intended for installaon on an outdoor pao or in your yard. It is highly
recommended that this appliance be installed in a sheltered area (following the guidelines outlined
below). Direct wind will cause an errac ame and possible pilot or main burner outage. An errac
ame could also lead to excessive carboning (black soot), this condion is not a safety issue but is visually
undesirable.
: When choosing a locaon for your appliance, care must be taken to avoid areas where excessive
moisture or running water may be a problem.
Any enclosure (shelter) in which the appliance is used must comply with one of the following:
With walls on all sides, but at least one permanent opening at ground level and no overhead cover.
Within a paral enclosure which includes an overhead cover and no more than two sidewalls. These
sidewalls may be parallel, as in a breezeway, or at right angles to each other.
Within a paral enclosure which includes an overhead cover and three sidewalls, as long as 30 percent or
more of the horizontal periphery of the enclosure is permanently open.