Installation Diagram
Before proceeding, it is important to consider the following height and length restrictions:
Before starting the installation, decide on the position of both the indoor and outdoor units.
Take into account the minimum clearance requirements for both the indoor and outdoor
units, which can be found in their respective sections of this manual.
Install the indoor unit inside the room to be air conditioned, avoiding corridors and
communal areas. Install the indoor unit at a height of at least 8 ft. off of the ground.
Page 23
6
Indoor Unit Installation Instructions
Indoor Unit
Installation
Outdoor Unit
Indoor Unit
Pipe length
is 50' max
Pipe length
is 50' max
Indoor Unit
Outdoor Unit
Height differential
must be less than 33 ft.
Height differential
must be less than 33 ft.
NOTE
Only persons and/or companies qualified and experienced in the installation, service, and repair of refrigerant
products should be permitted to do so. The purchaser must ensure the system is installed carefully and correctly.
For Systems of 18K and 24K BTU:
• The allowable height differential
increases to 49 ft.
• The allowable pipe length is 65 ft.
For Systems of 9K and 12K BTU:
• Follow the given constraints in the
figures to the left.