Integral Pump Maintenance
NOTE: This pump requires routine maintenance that is not covered by your 1 year parts
warranty. Only a defective pump will be repaired or replaced under the warranty.
As with all pumps, preventative maintenance is necessary to prevent issues from dirt
and slime that may accumulate in the drain system. This includes the drain pan, hose
to the condensate pump, pump reservoir, pump head, float assembly, and discharge
tubing
The pump is designed with quick connection construction, making it easy to access the
pump and components for service and maintenance.
To Remove Pump from Reservoir:
1. Unplug the unit.
2. Open the back housing as shown on page 12.
3. Remove the condensate tube from the pump.
4. Use the quick connect fittings to disconnect the main power and float switch electrical cables.
5. Use a flathead screw driver to gently pry the the pump off the reservoir.
At least once per year, clean your pump system.
Basic Pump Cleaning:
1. Press the pump button (PURGE) to drain any water from reservoir.
2. Disconnect power to the dehumidifier.
3. Mix a 16 oz cleaning solution of one of the following: 1 oz bleach / 15 oz water or 4 oz
white vinegar / 12 oz water. Pour the solution into the drain tray at the base of the coils.
NOTE: If you get any cleaning solution on the coils, flush with water
4. Allow cleaning solution to soak for 15 minutes.
5. Reconnect power to dehumidifier.
6. Pour clean water into reservoir so the pump activates twice (about 16-32 oz. water).
7. Repeat if needed or refer to Advanced instructions.
.
Access screws for electrical
compartment
Cover
Pump