Advanced Pump Cleaning:
1. a. Use the manual pump button (PURGE), to drain any water from reservoir.
b. Unplug the unit, and remove pump from reservoir (see page 13).
c. Use a wet dry vac or paper towels to remove any remaining water from the
pump reservoir.
2.
3.
4.
5.
6.
Fill the pump reservoir with cleaning solution (15 oz water / 1 oz bleach or 12 oz
water /4 oz white vinegar).
Reassemble the pump and use the manual pump button to flush the mixture
through the discharge tubing.
Mix another batch of cleaning solution then pour it slowly into drain pan under
evaporator coil and allow it to clean the hose from pan to pump. This process
can be stopped when the pump energizes 1 time.
NOTE: If you get any bleach/water mixture on coils, flush with water.
Pour sufficient clean water through the drain pan so that the pump activates
twice (16-32 ounces).
Reassemble the unit and return it to operational status.
Cleaning the Coils
The coils on your dehumidifier also need to be cleaned once per year. To clean,
simply spray with a self-rinsing, foaming coil cleaner (such as WEB Coil Cleaner).