Installation
32
This appliance is suitable for connection
with rigid pipe or flexible hose. The isolating
manual shut-off valve connection point must
be accessible when the appliance is
installed.
Flexible hose assembly must be certified to
AS/NZS 1869 class B or D, be of
appropriate internal diameter for the total
gas consumption (10mm), be kept as short
as possible (not exceeding 1200mm), must
not be in contact with the floor or any hot
surface or sharp surface. The hose
assembly must not be subject to strain,
abrasion, kinking, deformation, contact with
any other appliance or accidental contact
with oven flue outlet of an under bench
oven.
Gas leakage and operation of the
appliance must be tested by the installer
before leaving. Check burner flames are
blue in colour, stable and completely ignite
at both high and low flame settings with no
appreciable yellow tipping, carbon
deposition, lifting, floating, lighting back or
objectionable odour. Test burners
individually and in combination, When
satisfied with the operation of the cooker,
please instruct the user on the correct
method of operation
Natural Gas: the regulator must be fitted to
the appliance inlet connection. Gas
pressure must be adjusted to 1.0 kPa when
approximately 50% of the burners are on
high flame, the appliance test point is
located on the regulator.
Universal LPG: gas pressure must be
checked to confirm the appliance operating
pressure is 2.75 kPa.
1. Disconnect power.
2. Light the auxiliary burner and set to high
flame. Ensure all other burners are off.
3. Zero manometer, then apply flexible
tubing to seal over the Rapid burner
injector, hold securely in place and
check the gas pressure by pressing in the
corresponding burner control knob in,
then turning to high flame position.
4. If the pressure is 2.75 kPa, reassemble
the burner and perform the final checks
as per this instruction manual.
5. If the pressure is not 2.75 kPa, disconnect
the appliance and check/adjust/
replace the LPG cylinder regulator(s) as
appropriate in accordance with AS/
NZS 5601.