14 INSTALLATION INSTRUCTIONS
Insfallafion wifh opfional pedesfal base or slacking kif
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLA TION
• For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
*Required spacing
**For side or bottom venting,
2 inches (5.1 cm) spacing is allowed.
7"_(17.8 cm) 7,,*(17.8 cm)
,_ (22.9 cff 0
!
5"*_ 30" 1 "*_ 1" 27"
(12.7 cm)(76.1 cm) (2.5 cm) (2.5cm)(68.6 cm)(2.5 cm)
CLOSET VENTILATION REQUIREMENTS
Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One
upper vent opening with a minimum opening of 48 sq. in. (310 cm 2) must be installed no lower than 6 feet above the
floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm 2) must be installed no more than one
foot above the floor. One example shown uses vent grilles in the door.
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER
AND DRYER
• The dimensions shown are for tile recommended spacing.
*Required spacing
**For side or bottom venting,
2 inches (5.1 cm) spacing is allowed.
48 in.2 *
(310 crn2) 3_ (7.6 crn)
Z
7.6 cm_
24 in? *
(I 55 crn2)
_r_ 1"* (2.5 crn} 5w4"**
(14 crn)
6"* (15.3 crn)
68.6cm (2.5cm)