Smeg SSA91GGX2 Cooker with Gas Hob 90x60 cm

User manual - Page 17

For SSA91GGX2.

PDF File Manual, 23 pages, Read Online | Download pdf file

SSA91GGX2 photo
Loading ...
Loading ...
Loading ...
INSTALLATION - 1991477A487/A
e
6. Refit the cover. Ensure the moulded part of
the glass (A) is facing the door.
7. Press the cover completely down so that it
attaches perfectly to the bulb support.
INSTALLATION
Gas connection
Connection to the gas mains can be made using
a continuous wall steel hose in compliance with
the guidelines established by the standards in
force. To use other types of gas, see the chapter
Adaptation to different types of gas”. The
appliance's gas connector has a ½” external
thread (ISO 228-1).
Connection with a rubber hose
Verify that all following conditions are met:
The hose is attached to the hose connector
with safety clamps
No part of the hose is in contact with hot
walls (max. 50 °C)
The hose is not under traction or tension and
has no kinks or twists
The hose is not in contact with sharp objects
or sharp corners
If the hose is not perfectly airtight and leaks
gas, do not try to repair it; replace it with a
new hose
verify that the hose is not past its expiry date
(serigraphed on the hose itself).
Make the connection to the gas mains using a
rubber hose whose specifications comply with
current standards (verify that the reference
standard is stamped on the hose).
The appliance must be installed by a
qualified technician and according to
the regulations in force.
Appliance factory set for: LPG (G30/
31) at a pressure of 30-37 mbar.
See General safety instructions.
üü
Connection using a rubber hose
complying with current standards is only
permitted if the hose can be inspected
along its entire length.
The inside diameter of the hose must be
8 mm for LPG and 13 mm for Natural
gas and Town gas.
1
2
5
6
3
3
4
Loading ...
Loading ...
Loading ...