10
CONVERSIONS
10) REPLACING THE INJECTORS
The burners can be adapted to different types of gas
by installing injectors suited to the type of gas
required. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 15) and fit a injector corresponding to the type of
gas required.
It is advisable to tighten the injector in place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 7. The technician must reset any seals
on the regulating or pre-regulating devices and
affix the label corresponding to the new gas
regulation on the appliance instead of the already
existing one. This label is supplied in the packet
containing the spare injectors.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorised customer Service Centre.
For the sake of convenience, the nominal rate chart
also lists the heat inputs of the burners, the diameter
of the injectors and the working pressures of the
various types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
FIG. 15
*100 injector diameter and 13.0 MJ Nominal Heat Input for models with enamelled steel trivets.
U-LPG 2.75 94 11.5
2 RAPID NATURAL 1.00 155 12.0
U-LPG 2.75 106* 15.0*
1
ULTRA RAPID
NATURAL 1.00 176 15.0
U-LPG 2.75 73 6.9
3 SEMI-RAPID NATURAL 1.00 120 7.3
U-LPG 2.75 54 3.8
4 AUXILIARY NATURAL 1.00 90 4.0
U-LPG 2.75 94 11.5
5 FISH NATURAL 1.00 155 12.0
BURNERS
N° DESCRIPTION
GAS
NORMAL
PRESSURE
INJECTOR
DIAMETER
NOMINAL HEAT INPUT ( MJ/h )
(kPa) ( 1/100 mm ) MAX.
TABLE 1
Loading ...