Installing Foam Wet Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Remove power head and place in upside down position. Follow instructions to remove cartridge
lter.
3. Carefully slide foam wet lter down over the lter cage making sure the cage is completely
covered. (g. 2 & 3)
4. Place the power head onto the collection tank.
Cleaning Foam Wet Filter
1. With the removed power head in an upside down position, carefully remove foam wet lter. (g.
4)
2. Use a mild soap and water solution to wash foam wet lter and rinse with clean water. (g. 5)
3. Allow lter to air dry before installing and using again.
INSTALLING & CLEANING FOAM WET
FILTER
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING
Symptom Possible Causes Corrective Action
Vacuum will not operate.
1) No power supply. 1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord. 2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Collection tank full. 3) Empty collection tank.
Dust comes from motor cover.
1) The dust lter is missing or
damaged.
1) Attach or replace dust lter.
Reduced efciency and motor/
speed vibration.
1) There is a blockage in the
nozzle or hose, or the
collection tank inlet. Or dust
lter blocked by ne dust.
1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the lter
and clean it or install a new
lter.