Vacmaster VF408 1101 VF408 4 Gallon Wet/Dry Vacuum Cleaner with 2-Stage Motor

Operator’s manual - Page 10

For VF408 1101.

PDF File Manual, 13 pages, Read Online | Download pdf file

VF408 1101 photo
Loading ...
Loading ...
Loading ...
10
2 3 4 5 61
3 42
8
5 6
7
1
Installing Cartridge Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Remove power head and place in upside down position.
3. Install the cartridge lter over the lter cage and carefully push lter in until it stops against the
power head. (g. 2 & 3)
4. Place lter retainer on top of cartridge lter and tighten down by turning retainer clockwise. (g.
4 & 5)
Removing and Cleaning Cartridge Filter
1. Unlock and remove the lter retainer by turning retainer handle counter clockwise.
2. Carefully hold and pull the cartridge lter up for removal. (g. 6)
3. Clean the cartridge lter by gently tapping or brushing dirt off. Cleaning should not be done
indoors in living areas. For optimal performance a new lter is recommended.
4. Install cleaned or new lter as instructed above in steps 1 - 4 of Installing Cartridge Filter.
5. Wet lters should be removed and allowed to air dry for 24 hours before installing onto the lter
cage.
Installing and Cleaning HEPA Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Unlock the lter door by lifting the lock tab UP to the unlocked position and pull the door out. (g.
2 & 3)
3. Remove the HEPA lter cartridge from the vacuum. (g. 4)
4. Clean lter by brushing dirt off. For optimal performance a new lter is recommended. (g. 5)
5. Install the cleaned or new lter. (g. 6)
6. Insert the lter door tabs into the upper slots and lock the lter door into place. (g. 7 & 8)
INSTALLING & CLEANING CARTRIDGE
FILTER
Loading ...
Loading ...
Loading ...