WARNING
_,gas water heater cannot operate properly without the cor-
rect amount of air for combustion. Do not install in a confined
area such a closet, unless you provide air as shown in the
"Locating The New Water Heater" section. Never obstruct the
flow of ventilation air. If you have any doubts or questions at
all, call your gas company. Failure to provide the proper
amount of combustion air can result in a fire or explosion and
can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.
WARNING
If this water heater will be usedin beauty shops,barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the"Locafing
The New Water Heater" section of this manual and also the lat-
est edition of the National Fuel Gas Code, ANSI Z223.1, also
referred to as NFPA 54 for specifics provided concerning air
required.
WARNING
VENT DAMPERS - Any vent damper, whether it is operated
thermally or otherwise must be removed if its use _nhibits
proper drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fired water heaters
having thermal efficiency in excessof80% may produce a rel-
atively low flue gas temperature. Such temperatures may not
be high enough to properly open thermally operated vent
dampers. This would cause spillage of flue gases and may
:ause carbon monoxide polsonmg.
Vent dampers must bear evidenc(_of certification as complying
with the latest edition of American National Standard ANSI
Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and
mechanically actuated vent dampers). Before installation of
any vent damper, consult your local Sears Service Center or
the gas utility for further information.
WARNING
1. The appliance and its individual shutoff valve must be dis-
connectedfrom the gassupply piping system during any pres-
sure testing of the gassystem at test pressures in excessof 'A
pound per square inch (3.SkPa).
2. The appliance must be isolated from the gas supplypiping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressuresequal or less than ¼poundper square inch (3.5kPa).
WARNING -
Obstructed or deteriorated vent systemsmay present a serious
health risk or asphyxiation.
WARNING
Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spra_y..canprop.ellants, cleanin,g.soivents, reffig.erator and.air
conditioner refrigerants, swimming pool chemicals, calcium
and sodium chloride, waxes, bleach, and process chemicals
are typical compounds which are potentially corrosive.
WARNING
Minimum clearancesbetween the water heater and combustible
constructionare 1" at the sidesand rear, 4" at the front,and 6"
from the vent pipe. Clearance from the top of the jacket is 12".
Refer to the label on the water heater located adjacent to the
gascontrol valve for all clearances.
WARNING
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water systemthat has not been usedfor a long period of time
enerally two weeks or more). Hydrogen gas is extremely
mmabte and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical appliances which are connected to the :hot water
Systemare used (such asa dishwasher or washing machine). If
hydrogen gas is present, there will probably be an unusual
sound similar to air escapingthrough the pipeas the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it iSopen.
WARNING
INSULATING JACKETS: When installing an external water
heater insulation jacket on an gaswater heater:
a. DO NOT cover the temperature-pressurerelief valve.
b. DO NOT put insulation over any part of the top of the gas
water heater.
c. DO NOT put insulationover the gascontrol valve or gascon-
trol valve/burner cover,or any accessareasto the burner.
d. DO NOT let insulation around the gaswater heater to get
within 8 inchesof the floor (air must get to the burner).
e. DO NOT cover or remove operating instructions,and safety
related warning labels and materials affixed to the water
heater.
Failure to heed this will result in the possibility of a fire or
explosion.
WARNING
Scoot build-up indicates a problem that requires correction
beforefurther use.Turn"OFF"gasto waterheater and leave
"OFF"until repairsare made, _ecausefai|ure to correctthe
causeof the sootingcan resultin a fire or explosioncausing
DEATHSERIOUSBODILYINJURYORPROPERTYDAMAGE.
WARNING
The water heater with draft hood installed must be properly
vented to a chimney which terminates outdoors. Never oper-
ate the water heater unlessit isvented to the outdoors and has
_dequate air supply to avoid risks of improper operation,
_xplosion or asphyxiation.
CAUTION
WATER HEATERSEVENTUALLY LEAK:Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not
causedamageto the structure. When such locations cannot be
avoided, a suitable drain pan must be installed under the
water heater. Drain pans are available at your local Sears
Store. Such a drain pan must be not greater than 11½inches
deep, have a minimum length and width of at least 2 inches
greater than the water heater dimensionsand must Mepiped to
an adequate drain. Under no circumstancesisthe manufactur-
er or Searsto be held liable for any water damage in connec-
tion with this water heater.