Basic operation en
7
7.8 Switching off automatic mode
Press
or ⁠.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
7.9 Sensor sensitivity
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on. If the
sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Factory setting:5
¡ Lowest setting:0
¡ Highest setting:9
7.10 Setting the sensor sensitivity
1.
Press and hold
for approx.four seconds until the
setting is displayed.
2.
Press ⁠or to change the setting.
3.
To save the setting, press and hold ⁠for ap-
prox.fourseconds.
7.11 Switching on the lighting
The lighting can be switched on and off independently
of the ventilation system.
Press
⁠.
7.12 Switching on the AirFresh function
The fan runs for approx. fiveminutes per hour.
Press
⁠.
a appears in the display.
7.13 Switching off the AirFresh function
Press
⁠.
7.14 Switching on the NoiseReduction
function
1
The noise reduction function reduces the fan noise.
The function is possible in all fan settings, except in fan
setting
.
Press ⁠.
a The NoiseReduction function remains active even
after the appliance is switched off.
7.15 Switching on the audible signal
Press and hold
and at the same time for ap-
prox. threeseconds until a signal sounds.
7.16 Switching off the audible signal
Press and hold
and at the same time for ap-
prox. threeseconds until a signal sounds.
7.17 Saturation indicator
If the grease filters or odour filters are saturated, cor-
responding symbols flash after the appliance is
switched off.
Clean the saturated grease filters and, in doing so, ob-
serve the cleaning instructions in these instructions.
Change the saturated odour filters and observe the in-
structions in the accompanying instructions.
If odour filters can be regenerated, follow the instruc-
tions in the accompanying instructions.
7.18 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off,
ap-
pears in the display for the grease filter.
¡ After the appliance has been switched off, ap-
pears in the display for the odour filter.
¡ A signal sounds repeatedly.
Press
⁠.
a The saturation indicator is reset.
7.19 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
7.20 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched off.
1.
To set circulating-air mode for the standard odour
filter, press and hold
and until appears in
the display.
2.
To set circulating-air mode for the CleanAir standard
odour filter or the CleanAir Plus odour filter, press
and hold and repeatedly until appears in
the display.
3.
To set the exhaust-air mode, press and hold and
repeatedly until appears in the display.
1
Depending on the appliance specifications
Loading ...
Loading ...