PRODUCT OVERVIEW CONTINUED...
GENERAL INFORMATION
The Platinum Smart-Heat Gas radiant heaters are suitable for outdoor and non-residential indoor spaces. In addition to the
installation instructions provided, authorised installers must abide by the Australian installation code AS-5601-2010. Please
note that these standards are subject to change.
The heater is designed to function in winds up to 18Km/h. The heater is subject to reduced performance or failure in adverse
weather conditions such as high wind or extreme saturation.
PRODUCT FEATURES
Platinum gas radiant heaters are revolutionising the commercial outdoor and indoor heating industry by introducing
groundbreaking benefits never seen before in traditional gas or electric heaters. Platinum heaters have set the industry
benchmark with stylish good looks and world-first innovation.
Platinum heaters excel in the areas of:
Aesthetic appeal
Innovation
Performance
Flexibility
Cost effectiveness
For more detailed product information, visit www.platinumheating.com
INSTALLATION REQUIREMENTS
IMPORTANT
This appliance shall only be used in above ground open-air
situations with:
natural ventilation
without stagnant areas
where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection
Any enclosure in which the appliance is used shall comply
with one of the following:
1. An enclosure with walls on all sides, but at least one
permanent opening at ground level (ref. Appendix A,
Example 1)
2. Within a partial enclosure that includes an overhead
cover and no more than two walls (ref. Appendix A,
Example 2)
3. Within a partial enclosure that includes an overhead cover
and more than two walls, the following shall apply:
At least 25% of the total wall area is completely open
(ref. Appendix A, Example 4), and
At least 30% of the remaining wall area is open and
unrestricted (ref. Appendix A, Example 4)
4. In the case of Using this appliance/s for non-residential
indoor use:
This appliance must not be used in a room smaller
than 250 cubic meters (ref. Appendix A, Example 5)
This appliance must only be used in a well ventilated
area (ref. Appendix A, Example 5)
Note: The definition of outdoors is an above ground open-
air situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection.
!
GAS REQUIREMENTS
Platinum LPG Models:
Use Propane (LPG) gas only
The approved inlet pressure to the appliance is 2.75KPA
Platinum Natural Gas Models:
Use Natural Gas Only
Always use Bromic Natural Gas Governor (supplied) –
Model: BM-WF1A (AGA No. 5149)
Ensure that Inlet pressure to the regulator does not
exceed 5KPA
The approved inlet pressure to the appliance is 1.0KPA