32 - INSTALLATION 91477A884/B
The fuses blow or the circuit breaker of the
residential electrical system trips repeatedly.
Call Technical Support or an electrician.
There are cracks or fissures in the hob:
Turn off the appliance immediately,
disconnect the power supply and contact
Technical Support.
INSTALLATION
Gas connection
Connection to the gas mains can be made using
a continuous wall steel hose in compliance with
the guidelines established by the standards in
force. To use other types of gas, see the chapter
Adaptation to different types of gas”. The
appliance's gas connector has a ½” external
thread (ISO 228-1).
Connection with a steel hose
Make the connection to the gas mains using a
continuous wall steel hose whose specifications
comply with the applicable standard.
Carefully screw the connector 3 to the gas
connector 1 of the appliance, placing the seal 2
between them.
Connection with a steel hose with bayonet
fitting
Carry out the connection to the gas mains using
a steel hose with bayonet fitting compliant with
B.S. 669.
Apply insulating material to the thread of the gas
hose connector 4 and screw the adapter 3 onto
it. Screw the assembly onto the movable
connector 1 of the appliance, inserting the seal
provided 2 between them.
Connection with a steel hose with conical
fitting
Make the connection to the gas mains using a
continuous wall steel hose whose specifications
comply with the applicable standard.
Carefully screw the hose connector 3 to the
appliance’s gas connector 1 (½” thread ISO
228-1), placing the seal 2, provided, between
them. Apply insulating material to the thread of
connector 3 and then screw the steel hose 4
The appliance must be installed by a
qualified technician and according to
the regulations in force.
Appliance factory set for: natural gas
G20 at a pressure of 20 mbar.
See General safety instructions.